Skip Navigation View Sitemap

Outdoor cables (PVC)

A-Y(St)Y Bd Si Fca

A-Y(St)Y Bd Si Fca
in resemblance to DIN VDE 0815
Application

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power installation, but appropriate for underground installation.

Construction
  • Conductor: copper, solid, bare (Ø 0.8 mm)
  • Core insulation: PVC
  • Core stranding: 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping: plastic foil
  • Shield: tinned drain wire (Ø 0.8 mm); plastic-laminated aluminium foil
  • Outer sheath: PVC; colour: black RAL 9005 or blue RAL 5015 UV-resistant

A-Y(St)YCY Bd Si Fca

A-Y(St)YCY Bd Si Fca
in resemblance to DIN VDE 0815
Application

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power installation, but appropriate for underground installation.

Construction
  • Conductor: copper, solid, bare (Ø 0.8 mm)
  • Core insulation: PVC
  • Core stranding: 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping: plastic foil
  • Shield: tinned drain wire (Ø 0.8 mm); plastic-laminated aluminium foil
  • Sheath: PVC
  • Screen: tinned copper wire braid (Ø 0.2 mm); optical coverage approx. 80 %
  • Outer sheath: PVC; colour: black RAL 9005 or blue RAL 5015 UV-resistant

AJ-Y(St)YDY Bd Si Cu3,5 Fca

AJ-Y(St)YDY Bd Si Cu3,5 Fca
in resemblance to DIN VDE 0815
Application

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power installation, but appropriate for underground installation.

Construction
  • Conductor: copper, solid, bare (Ø 0.8 mm)
  • Core insulation: PVC
  • Core stranding: 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping: plastic foil
  • Shield: tinned drain wire (Ø 0.8 mm); plastic-laminated aluminium foil
  • Sheath: PVC
  • Weir / Screen: cross section 3.5 mm²; surrounded with 7 bare copper wires (Ø 0.8 mm); lapping with plastic foil
  • Outer sheath: PVC; colour: black RAL 9005 or blue RAL 5015 UV-resistant

AJ-Y(St)YDY Bd Si Cu16 Fca

AJ-Y(St)YDY Bd Si Cu16 Fca
in resemblance to DIN VDE 0815
Application

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power installation, but appropriate for underground installation.

Construction
  • Conductor: copper, solid, bare (Ø 0.8 mm)
  • Core insulation: PVC
  • Core stranding: 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping: plastic foil
  • Shield: tinned drain wire (Ø 0.8 mm); plastic-laminated aluminium foil
  • Sheath: PVC
  • Weir / Screen: cross section 16 mm²; surrounded with 16 bare copper wires (Ø 1.13 mm); lapping with plastic foil
  • Outer sheath: PVC; colour: black RAL 9005 or blue RAL 5015 UV-resistant

A-Y(St)YSY Bd Si Fca

A-Y(St)YSY Bd Si Fca
in resemblance to DIN VDE 0815
Application

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power installation, but appropriate for underground installation.

Construction
  • Conductor: copper, solid, bare (Ø 0.8 mm)
  • Core insulation: PVC
  • Core stranding: 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping: plastic foil
  • Shield: tinned drain wire (Ø 0.8 mm); plastic-laminated aluminium foil
  • Sheath: PVC
  • Armouring: galvanized steel wire braid (Ø 0.24 mm); optical coverage approx. 80 %
  • Outer sheath: PVC; colour: black RAL 9005 or blue RAL 5015 UV-resistant

A-LIYCY Bd Si Fca

A-LIYCY Bd Si Fca
in resemblance to DIN VDE 0815
Application

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power installation, but appropriate for underground installation.

Construction
  • Conductor: copper strand, bare; 7 x 0.3 mm = 0.5 mm² (Ø 0.9 mm)
  • Core insulation: PVC
  • Core stranding: 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping: plastic foil
  • Screen: tinned copper wire braid (Ø 0.2 mm); optical coverage approx. 80 %
  • Outer sheath: PVC; colour: black RAL 9005 or blue RAL 5015 UV-resistant

A-Y(St)Y-FR Bd Si Fca

A-Y(St)Y-FR Bd Si Fca
in resemblance to DIN VDE 0815
Application

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power installation, but appropriate for underground installation.

Construction
  • Conductor: copper, solid, bare (Ø 0.8 mm)
  • Core insulation: PVC
  • Core stranding: 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping: plastic foil
  • Shield: tinned drain wire (Ø 0.8 mm); plastic-laminated aluminium foil
  • Outer sheath: PVC-FR; colour: black RAL 9005 or blue RAL 5015 UV-resistant
Behaviour under fire conditions
  • Fire retardant: IEC 60332-3-22 / 24, DIN EN 60332-3-22 / 24
  • Low smoke and fume

A-Y(St)YCY-FR Bd Si Fca

A-Y(St)YCY-FR Bd Si Fca
in resemblance to DIN VDE 0815
Application

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power installation, but appropriate for underground installation.

Construction
  • Conductor: copper, solid, bare (Ø 0.8 mm)
  • Core insulation: PVC
  • Core stranding: 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping: plastic foil
  • Shield: tinned drain wire (Ø 0.8 mm); plastic-laminated aluminium foil
  • Sheath: PVC
  • Screen: tinned copper wire braid (Ø 0.2 mm); optical coverage approx. 80 %
  • Outer sheath: PVC-FR; colour: black RAL 9005 or blue RAL 5015 UV-resistant
Behaviour under fire conditions
  • Fire retardant: IEC 60332-3-22 / 24, DIN EN 60332-3-22 / 24
  • Low smoke and fume

AJ-Y(St)YDY-FR Bd Si Cu3,5 Fca

AJ-Y(St)YDY-FR Bd Si Cu3,5 Fca
in resemblance to DIN VDE 0815
Application

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power installation, but appropriate for underground installation.

Construction
  • Conductor: copper, solid, bare (Ø 0.8 mm)
  • Core insulation: PVC
  • Core stranding: 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping: plastic foil
  • Shield: tinned drain wire (Ø 0.8 mm); plastic-laminated aluminium foil
  • Sheath: PVC
  • Weir / Screen: cross section 3.5 mm²; surrounded with 7 bare copper wires (Ø 0.8 mm); lapping with plastic foil
  • Outer sheath: PVC-FR; colour: black RAL 9005 or blue RAL 5015 UV-resistant
Behaviour under fire conditions
  • Fire retardant: IEC 60332-3-22 / 24, DIN EN 60332-3-22 / 24
  • Low smoke and fume

AJ-Y(St)YCYDY-FR Bd Si Cu16 Fca

AJ-Y(St)YCYDY-FR Bd Si Cu16 Fca
in resemblance to DIN VDE 0815
Application

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power installation, but appropriate for underground installation.

Construction
  • Conductor: copper, solid, bare (Ø 0.8 mm)
  • Core insulation: PVC
  • Core stranding: 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping: plastic foil
  • Shield: tinned drain wire (Ø 0.8 mm); plastic-laminated aluminium foil
  • Sheath 1: PVC
  • Lapping: plastic foil
  • Screen: tinned copper wire braid (Ø 0.2 mm); optical coverage approx. 80 %
  • Sheath 2: PVC
  • Weir / Screen: cross section 16 mm²; surrounded with 16 bare copper wires (Ø 1.13 mm); lapping with plastic foil
  • Outer sheath: PVC-FR; colour: black RAL 9005 or blue RAL 5015 UV-resistant
Behaviour under fire conditions
  • Fire retardant: IEC 60332-3-22 / 24, DIN EN 60332-3-22 / 24
  • Low smoke and fume

A-Y(St)YSY-FR Bd Si Fca

A-Y(St)YSY-FR Bd Si Fca
in resemblance to DIN VDE 0815
Application

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power installation, but appropriate for underground installation.

Construction
  • Conductor: copper, solid, bare (Ø 0.8 mm)
  • Core insulation: PVC
  • Core stranding: 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping: plastic foil
  • Shield: tinned drain wire (Ø 0.8 mm); plastic-laminated aluminium foil
  • Sheath: PVC
  • Armouring: galvanized steel wire braid (Ø 0.24 mm); optical coverage approx. 80 %
  • Outer sheath: PVC-FR; colour: black RAL 9005 or blue RAL 5015 UV-resistant
Behaviour under fire conditions
  • Fire retardant: IEC 60332-3-22 / 24, DIN EN 60332-3-22 / 24
  • Low smoke and fume

AJ-Y(St)YDY-FR Bd Si Cu16 Fca

AJ-Y(St)YDY-FR Bd Si Cu16 Fca
in resemblance to DIN VDE 0815
Application

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power installation, but appropriate for underground installation.

Construction
  • Conductor: copper, solid, bare (Ø 0.8 mm)
  • Core insulation: PVC
  • Core stranding: 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping: plastic foil
  • Shield: tinned drain wire (Ø 0.8 mm); plastic-laminated aluminium foil
  • Sheath: PVC
  • Weir / Screen: cross section 16 mm²; surrounded with 16 bare copper wires (Ø 1.13 mm); lapping with plastic foil
  • Outer sheath: PVC-FR; colour: black RAL 9005 or blue RAL 5015 UV-resistant
Behaviour under fire conditions
  • Fire retardant: IEC 60332-3-22 / 24, DIN EN 60332-3-22 / 24
  • Low smoke and fume

A-Y(St)YSYö-FR Bd Si Fca

A-Y(St)YSYö-FR Bd Si Fca
in resemblance to DIN VDE 0815
Application

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power installation, but appropriate for underground installation. Resistant to impact of oils.

Construction
  • Conductor: copper, solid, bare (Ø 0.8 mm)
  • Core insulation: PVC
  • Core stranding: 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping: plastic foil
  • Shield: tinned drain wire (Ø 0.8 mm); plastic-laminated aluminium foil
  • Sheath: PVC
  • Armouring: galvanized steel wire braid (Ø 0.24 mm); optical coverage approx. 80 %
  • Outer sheath: PVC-FR; oil-resistant acc. DIN EN 60811-404, VDE 0473-811-404 edition 2012; colour: black RAL 9005
Behaviour under fire conditions
  • Fire retardant: IEC 60332-3-22 / 24, DIN EN 60332-3-22 / 24
  • Low smoke and fume

A-Y(St)YDSY-FR Bd Si Fca

A-Y(St)YDSY-FR Bd Si Fca
in resemblance to DIN VDE 0815
Application

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power installation, but appropriate for underground installation.

Construction
  • Conductor: copper, solid, bare (Ø 0.8 mm)
  • Core insulation: PVC
  • Core stranding: 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping: plastic foil
  • Shield: tinned drain wire (Ø 0.8 mm); plastic-laminated aluminium foil
  • Sheath: PVC
  • Weir / Rodent protection: galvanized steel shield (Ø 0.8 mm); optical coverage approx. 80%
  • Outer sheath: PVC-FR; colour: black RAL 9005 or blue RAL 5015 UV-resistant
Behaviour under fire conditions
  • Fire retardant: IEC 60332-3-22 / 24, DIN EN 60332-3-22 / 24
  • Low smoke and fume

A-LIYCY-FR Bd Si Fca

A-LIYCY-FR Bd Si Fca
in resemblance to DIN VDE 0815
Application

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power installation, but appropriate for underground installation.

Construction
  • Conductor: copper strand, bare; 7 x 0.3 mm = 0.5 mm² (Ø 0.9 mm)
  • Core insulation: PVC
  • Core stranding: 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping: plastic foil
  • Screen: tinned copper wire braid (Ø 0.2 mm); optical coverage approx. 80 %
  • Outer sheath: PVC-FR; colour: black RAL 9005 or blue RAL 5015 UV-resistant
Behaviour under fire conditions
  • Fire retardant: IEC 60332-3-22 / 24, DIN EN 60332-3-22 / 24
  • Low smoke and fume

A-LIYCYSY-FR Bd Si Fca

A-LIYCYSY-FR Bd Si Fca
in resemblance to DIN VDE 0815
Application

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power installation, but appropriate for underground installation.

Construction
  • Conductor: copper strand, bare; 7 x 0.3 mm = 0.5 mm² (Ø 0.9 mm)
  • Core insulation: PVC
  • Core stranding: 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping: plastic foil
  • Screen: tinned copper wire braid (Ø 0.2 mm); optical coverage approx. 80 %
  • Sheath: PVC
  • Armouring: galvanized steel wire braid (Ø 0.24 mm); optical coverage approx. 80 %
  • Outer sheath: PVC-FR; colour: black RAL 9005 or blue RAL 5015 UV-resistant
Behaviour under fire conditions
  • Fire retardant: IEC 60332-3-22 / 24, DIN EN 60332-3-22 / 24
  • Low smoke and fume

AJ-LIYCYDY-FR Bd Si Cu3,5 Fca

AJ-LIYCYDY-FR Bd Si Cu3,5 Fca
in resemblance to DIN VDE 0815
Application

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power installation, but appropriate for underground installation.

Construction
  • Conductor: copper strand, bare; 7 x 0.3 mm = 0.5 mm² (Ø 0.9 mm)
  • Core insulation: PVC
  • Core stranding: 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping: plastic foil
  • Screen: tinned copper wire braid (Ø 0.2 mm); optical coverage approx. 80 %
  • Sheath: PVC
  • Weir / Screen: cross section 3.5 mm²; surrounded with 7 bare copper wires (Ø 0.08 mm); lapping with plastic foil
  • Outer sheath: PVC-FR; colour: black RAL 9005 or blue RAL 5015 UV-resistant
Behaviour under fire conditions
  • Fire retardant: IEC 60332-3-22 / 24, DIN EN 60332-3-22 / 24
  • Low smoke and fume

A-LIY(St)YSY-FR PimF Bd Si Fca

A-LIY(St)YSY-FR PimF Bd Si Fca
in resemblance to DIN VDE 0815
Application

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power installation, but appropriate for underground installation.

Construction
  • Conductor: copper strand, bare; 7 x 0.3 mm = 0.5 mm² (Ø 0.9 mm)
  • Core insulation: PVC
  • Shielded pairs: each pair one layer plastic tape; drain wire: tinned copper strand 7 x 0.16 mm; one layer plastic laminated aluminium foil
  • Core stranding: 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping: plastic foil
  • Shield: tinned drain wire (Ø 0.8 mm); plastic-laminated aluminium foil
  • Sheath: PVC
  • Armouring: galvanized steel wire braid (Ø 0.24 mm); optical coverage approx. 80 %
  • Outer sheath: PVC-FR; colour: black RAL 9005 or blue RAL 5015 UV-resistant
Behaviour under fire conditions
  • Fire retardant: IEC 60332-3-22 / 24, DIN EN 60332-3-22 / 24
  • Low smoke and fume
Back to top