Skip to content
Installation Cables · based on DIN VDE 0815

JE-LIY(St)YSY-FR PimF Bd Si Fca

What the code means
J
installation cable
E
electronics
LI
bunched conductor to VDE 0812
Y
PVC
(St)
metal foil screen
Y
PVC
S
steel wire braid
Y
PVC
FR
flame retardant
PimF
pair in metal foil
Bd
unit stranding
Si
Simatic colour code
Fca
CPR class Fca to EN 13501-6
Decode another code

For information transmission in dry and moist production sites, in and under plaster, as well as outdoors for fixed installation. Not approved for power and underground installation.

Request this type Datasheet (PDF)
Key data
Standard
based on DIN VDE 0815
CPR class
Fca
Peak operating voltage
225 V
Temperature range during installation
-5°C to +50°C
Temperature range stationary
-30°C to +70°C
Minimum bending radius
15 x diameter
Datasheet
Download PDF
Type
JE-LIY(St)YSY-FR PimF Bd Si Fca
Shown
2 x 2 x 0.5
Core marking
VDE 0815
Schematic, not to scale.

Construction

  1. 1Conductor copper strand, bare; 7 x 0.3 mm = 0.5 mm² (Ø 0.9 mm)
  2. 2Core insulation PVC
  3. 3Shield tinned drain wire (Ø 0.8 mm); plastic-laminated aluminium foil
  4. 4Armouring galvanized steel wire braid (Ø 0.24 mm); optical coverage approx. 80%
  5. 5Outer sheath PVC-FR; colour: pebble grey RAL 7032 or blue RAL 5015
  • Shielded pairs each pair one layer plastic tape; drain wire: tinned copper strand 7 x 0.16 mm; one layer plastic laminated aluminium foil
  • Core stranding 2 cores to pair, 4 pairs to unit, units in layers; 2 x 2 as star quad
  • Lapping plastic foil

Choose your construction

All constructions from the datasheet. Select a row and enter a length to see weight, copper and bending radius.

6 constructions
JE-LIY(St)YSY-FR PimF Bd Si Fca: Dimensions, approximate diameter, cable weight and copper index
DimensionSheath mmØ mmkg/kmCu index kg/km
111.416228
1.21219850
1.217.437096
1.418.7445141
1.420.1570186
1.422.1645233

Need a different construction?

Ask us to check a variant. We confirm screening, dimensions, voltage and installation conditions together before proposing an alternative.

Quick inquiry - JE-LIY(St)YSY-FR PimF Bd Si Fca

Personal, technical advice for your inquiry.

When you submit the form, we process your information to handle your inquiry. Details can be found in our privacy policy.

Inquiry · personal and project-based

Send us your cable requirement.

Type, cross-section, quantity, delivery location: we review availability, price and lead time according to your enquiry. Personally and without unnecessary detours.

Request a quote info@tk-kabel.de
T. +49 (0) 7151 / 60 68 70

Inquiry list

Paste your bill of materials or collect types from the datasheet tables. We review every line and reply with availability, price and lead time.

From Excel, e-mail or PDF, one item per line. Or drop a file here.

The file is read in your browser and is not uploaded.

Items 0

No items yet. Paste your list above, or use “+ Inquiry” in the datasheet tables.

    Try LIYCY, halogen-free, drum, CPR or paste several lines.

    Enter opens · Esc closes

    Request a call back

    Leave your number and we will call you during office hours, Mon-Fri 9:00 a.m.-5:00 p.m. No form to fill in.

    When suits you?

    We only use your number for this call back. Details in our privacy policy.