- Armour
- Mechanical protection of steel wire or tape under the outer sheath, for example against pressure, tension or rodents.
- AWG
- American Wire Gauge, the US scale for conductor sizes. A higher number means a thinner conductor. Open tool →
- Bending radius
- The smallest permitted radius during installation, usually given as a multiple of the outer diameter. Fixed and moving cables often have different values.
- Braided screen
- A screen of braided copper wires. It stays flexible and is easy to terminate. Optical coverage states how dense it is.
- Bundle stranding
- Several pairs are grouped into bundles, and the bundles are stranded together. This is common for higher pair counts.
- Circuit integrity (E30, E90)
- The complete cable system including its supports keeps working in a fire for the stated time, 30 or 90 minutes. The system is tested, not just the cable.
- Compensating cable
- Connects a thermocouple to the instrument. Its conductors behave thermoelectrically like the thermocouple within a limited temperature range, but use a different, usually cheaper material.
- Conductor class
- Grouping under IEC 60228: class 1 solid, class 2 stranded, class 5 fine-stranded, class 6 extra fine-stranded. The higher the class, the more flexible the conductor.
- Copper surcharge
- A price addition that reflects the current copper quotation against an agreed base. The supplier sets the base and calculation. Open tool →
- CPR
- The EU Construction Products Regulation. Cables permanently installed in buildings carry a class for their reaction to fire, from Aca to Fca. Open tool →
- ETFE
- A fluoropolymer for insulation and sheath. Resistant to heat and chemicals, mechanically tough. Limits are in the relevant datasheet.
- FEP
- A fluoropolymer for insulation and sheath, resistant to high temperatures and many chemicals. Limits are in the relevant datasheet.
- Flame-retardant
- The material does not keep a flame going once the ignition source is gone. This does not mean the cable keeps working in a fire.
- FRNC, LSZH
- Flame Retardant Non Corrosive and Low Smoke Zero Halogen: flame-retardant and halogen-free, with little smoke and no corrosive fire gases.
- Halogen-free
- The material contains no chlorine, fluorine or bromine. A fire produces far fewer corrosive and toxic gases. This matters in tunnels, buildings and plants.
- Insulation integrity (FE180)
- The cable itself keeps its insulation under flame for the test duration. Unlike circuit integrity, this says nothing about the whole system.
- Optical coverage
- The share of the surface a braided screen covers, in per cent. It indicates how dense the screen is but does not replace a measured screening value.
- PVC
- Polyvinyl chloride, a versatile standard material for insulation and sheath. It contains chlorine, so it is not halogen-free. PVC-FR is the flame-retardant version.
- Rated voltage U0/U
- U0 is the voltage between conductor and earth, U the voltage between two line conductors, for example 0.6/1 kV. It states what the cable is designed for.
- Screen, shield
- A conductive layer around cores or pairs, usually foil, braid or both. It protects signals from outside interference and limits emissions.
- Silicone
- An insulation and sheath material that stays flexible at high and low temperatures. Mechanically more delicate than many other materials.
- Stranded conductor
- A conductor made of many thin wires. More flexible than a solid conductor, so it is common where cables move.
- Thermocouple, thermocouple cable
- Two different metals produce a temperature-dependent voltage at their junction. Thermocouple cables use the same materials as the thermocouple.
- Twisted pairs
- Two cores are twisted together. This reduces interference and crosstalk between signals.
- Voltage drop
- Voltage lost along the cable. It rises with current and length and falls with a larger cross-section.
- XLPE
- Cross-linked polyethylene, common in power cables. It tolerates higher conductor temperatures than PVC.